www.pairuigroup.com page: 1 / 4 date: 01/25/2014 constant voltage led drivers for outdoor use LEA-18V series, 18watt features: constant voltage output input voltage: 90-132vac short circuit, over voltage, and over temperature protections ip67 rated cooling by free air convection class , no fg pass lps (limited power source) test application for led lighting and electronic screen 100% burn-in test high reliability 2 years warranty model input voltage (vac) output voltage (vdc) output current (ma) output power (w) min. max. lea18-v12 90-132 12 0 1500 18 lea18-v24 24 0 750 18 lea18-v36 36 0 500 18 electrical input parameters symbols test conditions / comment min. typ. max. units input voltage v in --- 90 -- 132 vac input frequency f line --- 47 -- 63 hz input current i in full load, v in =115vac -- 0.5 -- a inrush current i inrush cold start, v in =115vac -- 40 -- a efficiency full load -- 82 -- % leakage current i leakage v in =115vac -- 0.25 -- ma
www.pairuigroup.com page: 2 / 4 date: 01/25/2014 constant voltage led drivers for outdoor use LEA-18V series, 18watt electrical output parameters symbols test conditions / comment min. typ. max. units output current i out lea18-v12 0 -- 1500 ma lea18-v24 0 -- 750 ma lea18-v36 0 -- 500 ma output voltage v out lea18-v12 -- 12 -- v lea18-v24 -- 24 -- v lea18-v36 -- 36 -- v output voltage accuracy -- --- -- 3 -- % line regulation i out-line --- -- 1.0 -- % load regulation i out-load --- -- 2.0 -- % turn-on delay time t on_delay v in =115vac, full load -- 1500 -- ms rise time t on_rise v in =115vac, full load -- 30 -- ms hold-on time -- v in =115vac, full load -- 20 -- ms ripple -- --- -- -- 200 mvp-p protection over current typical:>105%.hiccup mode, it will auto-reco very after fault conditions remove over voltage typical:110-150%; protection: turn off outpu t voltage, diode clamp type over temperature hiccup mode, it will auto-recovery after t emperature become normal environment storage t storage humidity: 5% rh to 95% rh -40 -- +80 ambient operating temperature t a startup at rated voltage (please refer to derating curve) -30 -- +70 temperature coefficient -- --- -- 300 -- ppm
www.pairuigroup.com page: 3 / 4 date: 01/25/2014 constant voltage led drivers for outdoor use LEA-18V series, 18watt electrical environment parameters symbols test conditions / comment min. typ. max. units operating relative humidity h a non condensing 10 -- 95 % mtbf t mtbf full load, 115vac input, 25 ambient temperature -- 1200.5 -- khrs dimension(lxwxh) 140x30x22mm weight 175g safety / emc safety standards ul1310 class 2, tuv en60950-1, en61347-2- 13,ip67 withstand voltage i/p-o/p:3kvac insulation resistance i/p-o/p: 100m ohms/500vdc/25 /70%rh emc emission design to en55022(cispr22)class b, en61000-3 -2 class a, en61000-3-3 emc immunity design to en61000-4-2,3,4,5,6,8,11, en55024 notes: 1. unless otherwise specified, all the above paramet ers are measured at ambient temperature of 25 and vin = 115vac, rated load; 2. ripple & noise are measured at 20mhz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1f & 47f parallel capacitor ; 3. suitable for indoor or outdoor which away from direct sunl ight conditions, avoid soaking in water for more than 30 minutes. mechanical unit: mm
www.pairuigroup.com page: 4 / 4 date: 01/25/2014 constant voltage led drivers for outdoor use LEA-18V series, 18watt mechanical recommend installation block diagram derating curve static characteristic curve 90 50 60 40 70 80 90 100 30 l o a d ( % ) input voltage vac at 60hz ( ) 100 110 120 132 140
|